        Welcome to the official website of Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.!
        Position首頁 > Home > Industrial Safety Products > Safety interlock switch > RFID Electromagnetic Locking Safety Door Switch
        D3SL-T/RFID electromagnetic locking type
        1.png

        ·Electromagnetic force locking 500N

        ·Adopt a small plane "electromagnetic" locking structure.

        ·Support 16 to 20 cascaded connections.

        ·Design of permanent magnet in matcher

        ·Small body, simple installation

        ·Full-angle eye-catching indicator light

        ·No abrasive powder will be produced.

        ·IP65/IP67 protection


        D3SL-T/RFID Series Selection Table

        Locking mode

        deploy

        model

        Output mode

        coded system

        Electromagnetic locking

        normalized form

        D3SL-T-DB-N2

        NPN

        universal coding

        D3SL-T-DB-N1

        NPN

        Unique coding

        D3SL-T-DB-P2

        PNP

        universal coding

        D3SL-T-DB-P1

        PNP

        Unique coding

        Advanced type

        D3SL-T-DG-N2

        NPN

        universal coding

        D3SL-T-DG-N1

        NPN

        Unique coding

        D3SL-T-DG-P2

        PNP

        universal coding

        D3SL-T-DG-P1

        PNP

        Unique coding


        Technical parameters of D3SL-T/RFID

        type

        Hinged door

        small-sized

        M12 connector

        normalized form

        High functional type

        working distance

        Sao(off-0n)

        4mm

        Sar(on-0ff)

        4mm

        Response time

        Lock → release

        155ms

        Release → lock

        155ms

        Detection → Non-detection

        20ms+2ms* (Number of cascaded connections -1)

        Non-detection → detection

        300ms+25ms* (Number of cascaded units -1)

        Control output

        (OSSD output)

        Output mode

        Transistor output "2

        Maximum load current

        150mA

        Residual voltage (on)

        Maximum ?2.5V (when the cable is 5m) and 3.5V (when the cable is 31m).

        OFF voltage

        Maximum ?2.0V (when the cable is 5m) and 3.0V (when the cable is 31m).

        leakage current

        Up to 0.5mA

        Maximum load capacity

        0.8uF

        Load connection resistance

        Max. 2.5 Euro

        AUX output

        (Non-safety system output)

        Output mode

        Transistor output

        Maximum load current

        50mA

        Residual voltage (ON)

        Maximum 2.5V (when the cable is 5m) and 3.5V (when the cable is 31m).

        external input

        (Short-circuit current)

        Safety input

        About 1.5 max 2

        Locking control input OSSD action switching input

        About 2.5 mA

        Reset /EDM input

        About 5mA (high functional type only)

        EDM select input

        About 2.5 mA (high functional type only)

        Power Supply 

        Power supply voltage

        24 VDC 10% including ripple (P-P)10% Class2

        consumed power

        <5W

        protective circuit

        Reverse connection protection of power supply, short circuit protection of outputs, surge protection of outputs and reverse connection protection of outputs.

        Environmental resistance

        Enclosure protection grade

        IP65/67(IEC60529)

        Operating ambient temperature

        20 degrees below zero to 55 degrees without freezing.

        Storage ambient temperature

        25 degrees below zero to 70 degrees without freezing.

        Using ambient humidity

        5% to 95%RH

        Storage environment humidity

        5% to 95%RH

        Vibration resistance

        10 to 55 Hz, double amplitude 2.0 mm, X, Y and Z directions for 5 minutes (IEC60947-5-3

        Applicable standards

        ENISO13849-1:2015(PLe,Category4), IEC60947-5-3,EN60947-5-3


        Model description of safety switch

         1728548977520914.png 



        hookup

        Standard type (NPN, cascade)

        Standard (PNP, cascade)

        1719978292858022.png

        Standard type (NPN, cascade)

        1719978426648983.png

        Standard (PNP, cascade)

        1719978725470017.png

        Functional (NPN, cascade)

        Functional (PNP, cascade)

        1719979076106539.png

        "Open and close linkage, purple is connected to 0V; Locking linkage purple disconnection

        "1. Use EDM and reset: wiring as shown in the figure.

        2. Do not use EDM and reset: connect EDM (pink line) and reset /EDM (light green) to +24V.

        3. Only use EDM: Turn off the EDM selection (pink line).

        K1.K2: External equipment (forced guided relay, electric and magnetic contactor, etc.)

        S: reset switch

        "Open and close linkage, purple is connected with +24V; Locking linkage purple disconnection

        "1. Use EDM and reset: wiring as shown in the figure.

        2. Do not use EDM and reset: connect EDM selection (pink line) and reset /EDM (light color recording) to 0V.

        3. Only use EDM: Turn off the EDM selection (pink line).

        K1.K2: External equipment (forced guided relay, electromagnetic contactor, etc.)

        S: reset switch

        High functional type (NPN, cascade)

        1719979521976024.png

        "Open and close linkage, purple is connected to 0V; Locking linkage purple disconnection

        1. Use EDM and reset: wiring as shown in the figure.

        2. Do not use EDM and reset: connect EDM (pink line) and reset /EDM (light green) to +24V;

        3. Only use EDM: Turn off the EDM selection (pink line).

        K1,K2: External equipment (forced guided relay, electromagnetic contactor, etc.)

        S: reset switch

        "Open and close linkage, purple is connected to 0V; Locking linkage purple disconnection

        1. Use EDM and reset: wiring as shown in the figure.

        2. Do not reset EDM: Select EDM (chalk line) and reset /EDM (light green) to+24V;

        3. EDM only: Turn off the EDM selection (chalk line).

        K1,K2: External equipment (forced guided relay, electromagnetic contactor, etc.)

        S: reset switch

        Functional (PNP, cascade)

        1719979875434469.png

        Open and close linkage, purple connected to +24V; Locking linkage purple disconnection

        1. Use EDM and reset: wiring as shown in the figure.

        2. Do not use EDM and reset: connect EDM (pink line) and reset /EDM (light green) to OV;

        3. Only use EDM: Turn off the EDM selection (pink line).

        K1,K2: External equipment (forced-guided dimensional appliances, electromagnetic contactors, etc.)

        S: reset switch

        Open and close linkage, purple connected to +24V; Locking linkage purple disconnection

        *1. Make ?EDM and reset: wire as shown in the figure.

        2. Do not reset EDM: Select EDM (chalk line) and connect reset /EDM (light green) to 0V;

        3. EDM only: Turn off the EDM selection (chalk line).

        K1,K2: External equipment (forced guided relay, electromagnetic contactor, etc.)

        S: reset switch


        Indication of indicator light

        1719983442751425.png


        Product ruler diagram

        1719983681983392.png


        Selection Method of Safety Switch D3SL-T/RFID Series

        1728618489514684.png



        Related Products
        Download
        PDF file download
        Video file download
        Previous

        Contact us

        400-881-6062

        Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

        E-Mail: info@lh-safety.com

        Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

        (Greenland East Coast International Plaza-Room A 313)

        Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

        Online service

        Online message

      2. Click to refresh
      3. 主站蜘蛛池模板: 亚洲日韩精品无码一区二区三区| 草肥熟老熟妇600部| 欧美日韩国产亚洲沙发| 中文幕无线码中文字夫妻| 中文字幕第四页| 免费无遮挡无码视频网站| 丝袜美腿一区二区三区四区 | 免费观看性行为视频的网站| 性欧美欧美巨大69| 成人午夜福利视频免费| 亚洲第一狼人伊人av| 色情无码一区二区三区| 国产一二三五区不在卡| 9色国产深夜内射| 欧美性猛交XXXX乱大交| 欧洲人妖区| 久久99九九精品久久久久蜜桃| 国产香蕉尹人在线观看视频| 一级天堂| 白嫩人妻精品一二三四区| 日本免费一区二区三区高清视频 | xxx综合网| 久久久久亚洲精品男人的天堂| 夜夜添无码试看一区二区三区| 亚洲欧美在线一区中文字幕| 91视频在线观看免费| 午夜亚洲国产理论片4080| 亚洲人成小说网站色在线| 亚洲理论在线A中文字幕| 国产主播一区二区在线观看| 亚洲色成人在线| 亚洲一级一区二区三区| 曰本女人牲交视频免费| 欧美亚洲综合成人A∨在线| 亚洲人成网线在线播放VA| 亚洲国产剧情在线精品视| 口爆AV| 岛国无码精品| 丰满少妇被猛烈进入av久久| 18禁亚洲深夜福利人口| 国产口爆|