<pre id="j6kov"></pre>
      1. <style id="j6kov"></style>
        男人到天堂在线a无码,国产婷婷色综合AV蜜臀AV ,日韩爱爱视频,日本亚洲乱码中文字幕影院,亚洲精品无码中文,久久99精品国产免费观观,国产欧美亚洲精品第3页在线,第一福利视频导航
        Welcome to the official website of Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.!
        Position首頁 > Home > Industrial Safety Products > Safety interlock switch > Magnetic induction switch
        LMC3-52 magnetic induction safety switch
        圖片1.png

        ·Miniaturized design,(compatible with 30mm aluminum frames) for easy installation.

        ·Adopts redundant internal circuits(dual CPU mutual inspection)and self-diagnostic function.

        ·Intelligent diagnosis and status display:Integrated LED indicators,provide real-time feedback on door switch status and fault information, facilitating quick troubleshooting.

        ·Support series connection of multiple switches(up to 30 switches can be connected),adapting to complex equipment layouts.

        ·The actuator coding function has low-level and high-level settings. It performs self-learning to match the sensor during initial installation. The high level function is unique and non-interchangeable.

        ·Equipped with magnetic latching function,with a magnetic holding force of up-to 15N,which can replace door magnets.


        395181ccb7a771e30162f6415dc922a.png

        Selection catagory

        Configuration type

        Coding type

        Output mode

        Lead wire mode

        Direct outlet

        Cable length

        Model

        Basic function

        Universal coding

        NPN

        Direct outlet

        3M

        LMC3-52-J2-N-Z3

        5M

        LMC3-52-J2-N-Z5

        10M

        LMC3-52-J2-N-Z10

        M12 Connector

        /

        LMC3-52-J2-N-M12

        PNP

        Direct outlet

        3M

        LMC3-52-J2-P-Z3

        5M

        LMC3-52-J2-P-Z5

        10M

        LMC3-52-J2-P-Z10

        M12 Connector

        /

        LMC3-52-J2-P-M12

        Unique coding

        NPN

        Direct outlet

        3M

        LMC3-52-J1-N-Z3

        5M

        LMC3-52-J1-N-Z5

        10M

        LMC3-52-J1-N-Z10

        M12 Connector

        /

        LMC3-52-J1-N-M12

        PNP

        Direct outlet

        3M

        LMC3-52-J1-P-Z3

        5M

        LMC3-52-J1-P-Z5

        10M

        LMC3-52-J1-P-Z10

        M12 Connector

        /

        LMC3-52-J1-P-M12

        Standard

        Universal coding

        NPN

        Direct outlet

        3M

        LMC3-52-B2-N-Z3

        5M

        LMC3-52-B2-N-Z5

        10M

        LMC3-52-B2-N-Z10

        M12 Connector

        /

        LMC3-52-B2-N-M12

        PNP

        Direct outlet

        3M

        LMC3-52-B2-P-Z3

        5M

        LMC3-52-B2-P-Z5

        10M

        LMC3-52-B2-P-Z10

        M12 Connector

        /

        LMC3-52-B2-P-M12

        Unique coding

        NPN

        Direct outlet

        3M

        LMC3-52-B1-N-Z3

        5M

        LMC3-52-B1-N-Z5

        10M

        LMC3-52-B1-N-Z10

        M12 Connector

        /

        LMC3-52-B1-N-M12

        PNP

        Direct outlet

        3M

        LMC3-52-B1-P-Z3

        5M

        LMC3-52-B1-P-Z5

        10M

        LMC3-52-B1-P-Z10

        M12 Connector

        /

        LMC3-52-B1-P-M12

        High-function typle


        Universal coding

        NPN

        Direct outlet

        3M

        LMC3-52-G2-N-Z3

        5M

        LMC3-52-G2-N-Z5

        10M

        LMC3-52-G2-N-Z10

        M12 Connector

        /

        LMC3-52-G2-N-M12

        PNP

        Direct outlet

        3M

        LMC3-52-G2-P-Z3

        5M

        LMC3-52-G2-P-Z5

        10M

        LMC3-52-G2-P-Z10

        M12 Connector

        /

        LMC3-52-G2-P-M12

        Unique coding

        NPN

        Direct outlet

        3M

        LMC3-52-G1-N-Z3

        5M

        LMC3-52-G1-N-Z5

        10M

        LMC3-52-G1-N-Z10

        M12 Connector

        /

        LMC3-52-G1-N-M12

        PNP

        Direct outlet

        3M

        LMC3-52-G1-P-Z3

        5M

        LMC3-52-G1-P-Z5

        10M

        LMC3-52-G1-P-Z10

        M12 Connector

        /

        LMC3-52-G1-P-M12


        395181ccb7a771e30162f6415dc922a.pngModel description

        1750041376195449.png



        395181ccb7a771e30162f6415dc922a.pngM12 Connection cable selection

        M12 connection cable

        image.png

        Basic function cable(5-pin, 5-core)

        LMC3-52--XL-P55C3

        LMC3-52-XL-P55C5

        LMC3-52-XL-P55C10

        Standard-type cable(8-pin,8-core)

        LMC3-52-XL-P88C3

        LMC3-52-XL-P88C5

        LMC3-52-XL-P88C10

        High-function type cable(12-pin,10-core)

        LMC3-52-XL-P1210C3

        LMC3-52-XL-P1210C5

        LMC3-52-XL-P1210C10


        395181ccb7a771e30162f6415dc922a.pngIndicator light description

        image.png


        Indicator light name

        Light color

        Status

        Status description

        Status of OSSD

        Detection status of the actuator

        Large indicator light

        Green

        Light up

        In normal operation

        ON

        Detection status

        Green

        Flashing

        (high- speed)

        Switching coding level from low to high, or teaching the matcher

        OFF

        Detected matcher is incorrect

        Green

        Flashing

        Switching coding level from low to high, or teaching the matcher

        OFF

        Detected matcher is incorrect

        Red and green alternating

        Flashing

        (high- speed)


        An untaught actuator is detected when operating at "high" coding level

        OFF

        Detected matcher is incorrect

        Error during coding level switching

        Not fixed

        Red

        Light up

        Door is in open state.

        OFF

        Non-detection status

        Flashing

        (high- speed)


        Error state.The sensor detects an abnormality

        OFF

        Not fixed

        Turn off

        Power OFF

        OFF

        Not fixed

        OSSD indictor light

        Green

        Light up

        OSSD is on

        ON

        Detection status

        Flashing

        OSSD is on,but the door is in an unstable state such as half-open

        ON

        Detection status

        Red

        Light up

        OSSD is off

        OFF

        Not fixed

        Input indicator light

        Green

        Light up

        Safety input is on

        Not fixed

        Detection status

        Flashing

        Self- holding release waiting state(waiting for reset input)

        OFF

        Not fixed

        Turn off


        Safety input is OFF,or other states.

        OFF

        Detection status


        395181ccb7a771e30162f6415dc922a.pngTechnical parameter

        Model

        LMC3-52-J

        LMC3-52-B

        LMC3-52-G

        Type

        Basic function type

        Standard type

        High-function type

        Detection distance


        Front side

        sao(OFF→ON)

        10mm

        sar(ON→OFF

        18mm

        Side face

        sao(OFF→ON)

        6mm

        sar(ON→OFF

        14mm

        Response time(ms)*1

        Detection action

        Detection→Non-detection

        20ms+2ms×(total number of cascade-connected units -1)

        Non-detection→ Detection

        30ms+25ms×(total number of cascade-connected units-1)

        Door operation

        Allowable operating frequency

        3Hz

        Magnetic attraction

        Magnetic holding force

        15N

        Cascade connection

        Standard

        -

        Maximum 30 units

        Control output(OSSD output)

        Output type

        Transistor output×2

        Maximum load current

        PNP:<=150mA、NPN:<=100mA

        Residual voltage during ON state

        Maximum 2.5V(with 5m cable)

        Voltage in OFF state

        Maximum 2.0V(with 5m cable)

        Leakage current

        Maximum 0.5mA

        Maximum load capacity

        2.2μF

        Load wiring resistance

        Maximum 2.5Ω

        Detection distance

        Front side

        sao(OFF→ON)

        10mm

        sar(ON→OFF

        18mm

        Side face

        sao(OFF→ON)

        6mm

        sar(ON→OFF

        14mm

        Response time(ms)*1

        Detection action

        Detection→Non-detection

        20ms+2ms×(total number of cascade-connected units-1 )

        Non-detection→ Detection

        30ms+25ms×(total number of cascade-connected units-1 )

        Door operation

        Allowable operating frequency

        3Hz

        Magnetic attraction

        Magnetic holding force

        15N

        Cascade connection

        Standard

        -

        Maximum 30 units

        Control output(OSSD output)

        Output type

        Transistor output×2

        Maximum load current

        PNP:<=150mA、NPN:<=100mA

        Residual voltage during ON state

        Maximum 2.5V(with 5m cable)

        Voltage in OFF state

        Maximum 2.0V(with 5m cable)

        Leakage current

        Maximum 0.5mA

        Maximum load capacity

        2.2μF

        Load wiring resistance

        Maximum 2.5Ω

        AUX output(Non-safety system output)

        Output type

        Transistor output

        Number of outputs

        1

        Maximum load current

        50mA

        Residual voltage during ON state

        Maximum 2.5V(with 5m cable)

        External input (Short-circuit current)

        Safety input

        -

        Approximately 1.5mA×2

        Reset/EDM Input

        -

        Approximately 5mA×1

        Power supply

        Power supply voltage

        24VDC±20% including ripple(P-P)10%Class2

        Power comsuption

        0.8W*2

        Protection circuits

        Power reverse connection protection、each output short-circuit protection、eacn output surge protection、output reverse connection protection

        Safety related parameters

        ISO13849-1 IEC/EN60947-5-1 IEC/EN60947-5-3

        Compliant with ISO 13849-1 catagory 4 switch /suitable for PLe/PLd

        MTTFd≥30 years

        CE

        Environmental resistance

        Enclosure protection class

        IP65,IP67IP68 requires customization,pls consult the sales department before placing an order

        Operating ambient temperature

        -20℃ to +55℃(No freezing)

        Storage ambient temperature

        -25℃ to +70℃(No freezing)*3

        Operating ambient humidity

        5% to 95%RH

        Storage ambient humidity

        5% to 95%RH

        Vibration resistance

        10 to 55HZ、double amplitude 3.0mm、5 minutes for each directions X、Y、Z

        (IEC60947-5-3)

        Shock resistance

        30G,6 times for each direction X、Y、Z(IEC60947-5-3)

        Material

        Sensor

        Host server

        Housing

        Flame-retardant grade thermoplastic

        Cable

        PVC

        Matcher

        Housing

        Flame-retardant grade thermoplastic

        *1 The risk time specified in IEC60947-5-3 is 150 ms+2 ms×(total number of cascade-connected units-1) 

        *2 Excluding load current。

        *3 For long-term storage ,pls store in an environment below 55℃

        395181ccb7a771e30162f6415dc922a.pngProduct dimension drawing

        1750041793170171.png1750041831401457.png


        395181ccb7a771e30162f6415dc922a.pngWiring diagram

        1750042721223258.png

        Pin number

        Signal definition

        Color

        Description

        1

        24V

        Brown

        Positive power supply

        2

        OSSD2

        White

        safety output 2

        3

        0V

        Blue

        Negative power supply

        4

        OSSD1

        Black

        safety output 1

        5

        AUX output

        Gray

        Auxiliary output 1


        1750042818626171.png

        Pin number

        Signal definition

        Color

        Description

        1

        AUX output 1

        Gray

        Auxiliary output 1

        2

        24V

        Brown

        Positive power supply

        3

        Not used

        Red

        Not used

        4

        safety input 2

        Yellow

        Cascade input 2

        5

        OSSD1

        Black

        safety output 1

        6

        OSSD2

        White

        safety output 2

        7

        0V

        Blue

        Negative power supply

        8

        safety input 1

        Green

        Cascade input 1


        1750043082195521.png

        Pin number

        Signal definition

        Color

        Description

        1

        24V

        Brown

        Positive power supply

        2

        Safety input 1

        Green

        cascade input 1

        3

        0V

        Blue

        Negative power supply

        4

        OSSD1

        Black

        Safety output 1

        5

        AUX output1

        Gray

        Auxiliary output 1

        6

        Safety input 2

        Yellow

        cascade input 2

        7

        OSSD2

        White

        Safety output 2

        8

        Self-holding/EDM selection input

        Pink

        Self-holding/EDM selection input

        9

        Not used

        Red

        Not used

        10

        11

        Reset/EDM input

        Purple

        Reset/EDM input

        12

        1750045067392088.png1750045195573398.png1750045324661430.png
        Wiring example for cascade connection

        High-functioning self-protection function:

        圖片3.png

        The self-protection function is a feature that prevents the OSSD from automatically switching from OFF state to ON state. This function can prevent accidental startup or restart of the device. To restore from the state where the self-protection is active to the normal operating state, a reset operation is required.

        The basic function type and standard type can not set the self-protection function. The self-protection function is fixed to "Automatic"

        The self-protection function of high-function type can be selected from two types:"Automatic"and"Manual".

        "Automatic"and"Manual" here refer to following actions:

        Automatic:

        When the OSSD meets the condition for switching to the ON state(for example, the door is in the closed state), it shall switch to the ON state immediately.

        Manual:

        Even if the OSSD meets the condition for switching to the ON state, it shall remain in the OFF state(self-holding state).

        <Release of self-holding state>

        To switch the OSSD to the ON state and start the equipment, a reset operation must be performed under the conditions that the door with GS(non-contact)installed is closed and the equipment is ready for startup.Through this,the OSSD will switch to the ON state,and the self-holding state can be released.

        Setting of Self-holding function

        Self-holding function

        EDM function

        Reset/EDM input(Purple)

        Self-holding/EDM function selection input(Pink)

        Automatic

        Not in use

        0V

        0V

        Automatic

        in use

        Connect to 24 V via NC contact of relay

        Open

        Manual

        Not in use

        Connect to 24 V via NO reset switch

        Connect to 24 V

        Manual

        in use

        Connect to 24V via NO reset switch and NC contact of relay

        Connect to 24 V



        Related Products
        Download
        PDF file download
        Video file download
        Previous

        Contact us

        400-881-6062

        Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

        E-Mail: info@lh-safety.com

        Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

        (Greenland East Coast International Plaza-Room A 313)

        Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

        Online service

        Online message

      2. Click to refresh
      3. 主站蜘蛛池模板: 91久久偷偷做嫩草影院| 中文字幕一区二区三区又粗| 久久综合激情网| 亚洲日韩欧美国产高清αv| 2020年无码国产精品高清免费| 日本一区三区高清视频| 激情六月丁香婷婷四房播| 97人妻精品一区二区三区软件| 91丨九色丨人妻丨白浆| 国产美女爽到喷出水来视频| 色五月五月丁香亚洲综合网| 黑人videos特大hd粗暴| 久久精品国产99久久久古代| 玩弄丰满少妇人妻视频| 中文字幕色av一区二区三区| 欧美性交网| 视频二区素人国产模特| 午夜在线观看成人av| 中文字幕一区二区三区久久| 亚洲中文人妻在线| 国产精品VA在线观看老妇女 | 精品无人区一码二码三码| 伊人久久精品| 亚洲中文字幕日产喷水| 91丨九色丨人妻丨白浆| 亚洲最大福利视频网| 免青青草免费观看视频在线| 亚洲无码精品在线播放| 无码乱肉视频免费大全合集| 国产成人精品亚洲精品日日| av动态| 欧美中出无码| 中国国产高清免费AV片| 一区二区亚洲人妻av| 1024手机看片你懂的人妻69| 国内综合无码| 久久天天躁夜夜躁狠狠820175| 国产精品污双胞胎在线观看| 久久久久免费看黄a片app| 日韩av无码精品人妻系列| 国产午夜亚洲精品久久|