        SPC series programmable safety controller

        SPC series programmable safety controller
        圖片1.png

        · Modular structure: The system adopts a combined structure of "main control module+expansion module".One main control module can connect up to 14 IO modules and 2 EN modules. It supports communication between multiple main control modules.

        · Safety inputs: up to 132, supporting digital and switching signal inputs.

        · Safety outputs: up to 84,with PNP transistor outputs.

        · Function blocks: up to 255 basic logic operation blocks and specific function blocks can be used. The basic logic operation blocks include AND,OR,NOT,XOR,XNOR,RS trigger,and delay function blocks.The specific function blocks include encoder monitoring,radar monitoring,emergency stop monitoring, switch monitoring,reset, light curtain monitoring, two-hand monitoring,mode selection monitoring and EDM.

        · Encoder interfaces:Up to 12, supporting:A/B incremental encoders(maximum frequency 500KHz),sine-cosine incremental encoders(maximum frequency 120KHz),and SSI encoders(maximum baud rate 500KHz).

        · Communication interfaces:Supporting Ethernet, CAN, RS485 and Type C


        Model specification

        Product selection

        Type

        Number of inputs/channels

        Number of outputs/channels

        Communication

        Maximum quantity

        SPC-1000-AGV

        Main control module

        12

        8

        ETH、CAN、

        Type C

        1

        SPC-1000

        20

        8

        ETH、RS485

        Type C

        1

        SPC-SIO8

        Expansion module

        8

        4

        -

        14

        SPC-SIO12

        0

        0

        -

        2


        Technical parameter

        Safety parameter

        Safety integrity level

        SIL 3(IEC 61508 、IEC 62061)

        Safety performance level

        PL e(ISO 13849-1)

        Architecture category

        Cat.4(ISO 13849-1)

        PFHD

        <10-7

        TM(Continuous operating time)

        20 years(ISO 13849-1)

        Electrical parameters

        System power supply(V+ 、V-)

        24V DC(70%~ 125%)

        Output power supply(DC24V 、0V)

        24V DC(70%~ 125%)

        Power consumption(no load)

        MC12:5.5W

        MC20:3.5W

        IO:2.5W

        EN:3W

        Overvoltage category

        Class Ⅱ(EN 61131-2)

        Power-on start-up time

        ≤15s

        Response time

        Tmin=4ms ,see the hardware manual for details

        Safety input

        ON state:input voltage:13~28V

        OFF state :input voltage:0~5V

         

         

        safety output

        Output type:PNP semiconductor

        ON state:output voltage DC24V,rated current 300mA ,Output voltage drop≤2V

        OFF state : Residual voltage ≤1V , leakage current ≤0.5mA

        Maximum capacitive load:0.9uf

        Data communication

        CAN 、RS485 、Ethernet communication

        Configuration interface

        Type C 、ETH

        Display screen

        1.54 inches OLED

        Environmental parameters

        Operating temperature and humidity

        Open environment:-25℃~60℃

        Relative humidity 10%~95% ,No condensation

        Storage temperature and humidity

        -25℃~70℃

        Relative humidity 10%~95% ,No condensation

        Shock resistance

        15g,11ms Half sine wave(EN 61131-2)

         

        Vibration resistance

        5Hz~8.4Hz ,3.5mm,displacement,Constant amplitude;

        8.4Hz~150Hz ,1g acceleration,Constant amplitude(EN 61131-2)

        Protection level

        IP20(EN 60529)

        Insulation protection

        Class Ⅲ(SELV)(EN 61131-2)

        EMC

        EN 61131-2 、IEC 61326-3-1

        Environmental requirements

        RoHS 10 items

        Flame retardancy

        UL94-V1


        Product dimension diagram

        圖片2.png


        Wiring diagram

        System power supply:

        1754359937326226.png

        Emergencey stop button:

        1754359955995980.png

        Two-hand button:

        1754359969647925.png

        Light curtain:

        1754359986695893.png

        Reset:

        1754360003372869.png

        Safety output and EDM:

        1754360020919161.png1754360040745092.png




        Related Products
        Download
        PDF file download
        Video file download
        Previous

        Contact us

        400-881-6062

        Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

        E-Mail: info@lh-safety.com

        Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

        (Greenland East Coast International Plaza-Room A 313)

        Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

        Online service

        Online message

      2. Click to refresh
      3. 主站蜘蛛池模板: 久久国产精品二国产人妻| 欧美疯狂xxxxbbbb喷潮| 全部免费播放在线毛片| 91精品国产色综合久久不卡蜜| 国产高潮又爽又刺激的视频 | 青草青草久热精品视频在线观看| 3751色视频| www.97超碰| 人人妻人人澡人人爽精品欧美| 久久综合给合久久狠狠97色| 成人国产精品免费网站| 无码AV在线播放| 国产成人无码www免费视频播放| 屁屁影院国产第一页| 97无码免费人妻超级碰碰碰| 欧美s码亚洲码精品m码| 亚洲中国精品精华液| 国产偷人妻精品一区二区在线| 高清免费毛片| 国产午夜视频| 两性午夜刺激性视频| 国产成人精品午夜福利在线观看 | 无码AV无码免费一区二区| 亚洲AV亚洲| 久久国产精品亚洲va麻豆| 日本真人做爰免费视频120秒| 亚洲国产精品黄在线观看| 久章草在线毛片视频播放| 亚洲欧美人成网站在线观看看| 一本一道人妻久久综合无码| 1精品啪国产在线观看免费牛牛| 尤物在线观看精品国产福利片| 日本一卡2卡3卡四卡精品网站| 国产一区二区午夜福利久久| 67194熟妇在线观看线路| 色综合视频一区二区三区44| 综合一区二区| 免费国产a国产片高清网站| 国产年成美女网站视频免费看| 无码日韩人妻精品久久蜜桃| 在线看高清中文字幕一区|